N123.4MCY Nexans LANmark-OF Pigtail SC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
21.00 AEDAdd to cartN123.4MCY Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF SM pigtails have LANmarkOF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITUT G.657.A1 and to IEC 60793250, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or MicroBundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
N205.617 Nexans Duplex LC Snap-In Adaptor Multimode Aqua
23.00 AEDAdd to cart11.4mm
Technical Specifications
Insertion Loss: < 0.2 dB
Sleeve Preservation Strength: 2.0 ~ 5.9N (200gf ~600gf)
JIS Z9015 standard l: 1 time pull out
NAMl test AQL = 0.25%
Plug Connect/Disconnect Strength: Less than 19.6N (2Kgf)
Sealing Pull Strength: Less than 98.0N (10Kgf)
Plug Removal Strength: Less than 68.6N (7Kgf)N205.617 Nexans LANmark-OF Snap-In Adaptor
21.50 AEDAdd to cartN205.617 Nexans
DESCRIPTION
LANmark-OF Snap-In adaptors have been designed for installation into the LANmark-OF snap-in panels, ZD boxes and outlets. They are available in single SC, duplex SC and duplex LC duplex. The multimode adaptors are aqua, the singlemode adaptors are blue while the singlemode APC adaptors are green. Installation time is saved as the snap-in concept replaces the time-consuming screwing attachment of the traditional adaptors.
N205.624 Nexans Adapter DSC-DSC Single mode
30.00 AEDAdd to cartNexans N205.624
LANmark-OF Snap-in Adapter DSC-DSC Single mode
Description
LANmark-OF snap-in adapters have been designed for snapping into the
modular OF patch panels and ZD boxes. They are available in single SC,
dual SC, LC duplex and MT-RJ version. The 2 Small Form Factor connector
types offer double density, as two fiber connections are offered on the SCtype
footprint. Installation time is saved as the snap-in concept replaces
the time-consuming screwing attachment of coupling devices.
Materials
· Adapter Housing: PBT, 15% Glass
· Sleeve Holder: PBT, 20% Glass
· Dust Cap: PP
· Spring:SUS 304 CSP 3/4 H
· PB Sleeve: PB – inner diameter 2,48mm – length 11.4mm
· Zirconia Sleeve: ZA Ceramic – inner diam.: 2.48mm -length11.4mm
Technical Specifications
Insertion Loss: < 0.2 dB
Sleeve Preservation Strength: 2.0 ~ 5.9N (200gf ~600gf)
JIS Z9015 standard l: 1 time pull out
NAMl test AQL = 0.25%
Plug Connect/Disconnect Strength: Less than 19.6N (2Kgf)
Sealing Pull Strength: Less than 98.0N (10Kgf)
Plug Removal Strength: Less than 68.6N (7Kgf)- Fiber Optic Duplex Connectors, Fiber Optic Simplex Connectors, Fiber optical Patch Panel, Fibre Networking, NEXANS
N205.624 Nexans LANmark-OF Duplex SC Snap-In Adaptor Singlemode
30.10 AEDAdd to cartN205.624 Nexans
DESCRIPTION
LANmark-OF Snap-In adapters have been designed for installation into the LANmark- OF snap-in panels, ZD boxes and outlets. They are available in single SC, duplex SC and duplex LC duplex. The multimode adaptors are aqua, the singlemode adaptors are blue while the singlemode APC adaptors are green. Installation time is saved as the snap-in concept replaces the time-consuming screwing attachment of coupling devices.
N205.627 Nexans LANmark_OF_Duplex_LC_Snap_In_Adaptor_Singlemode
37.20 AEDAdd to cartN205.627 Nexans
DESCRIPTION
LANmark-OF Snap-In adaptors have been designed for installation into the LANmark- OF snap-in panels, ZD boxes and outlets. They are available in single SC, duplex SC and duplex LC duplex. The multimode adaptors are aqua, the singlemode adaptors are blue while the singlemode APC adaptors are green. Installation time is saved as the snap-in concept replaces the time-consuming screwing attachment of the traditional adaptors.
N420.66A Nexans Connector Category 6A
23.00 AEDAdd to cartN420.66A Nexans
Connector Category 6A
DESCRIPTION
Nexans LANmark-6A Evo Snap-In Connectors are manufactured and tested to the
latest Category 6A specifications defined in the International and American cabling
standards and are designed to meet or exceed the stringent quality and performance
criteria needed to support all applications up to 500 MHz, including 10 Gigabit
Ethernet.
A fully closed metal rear cover providing 360 degrees shielding offers excellent
coupling attenuation and ensures immunity from Alien Crosstalk and other external
interferences.
Channels built with LANmark-6A cables and jacks do not need on site testing for Alien
Crosstalk, as this parameter is met by design. This significantly reduces the installation
cost for 10G network cabling.
· 10 BASE-T Ethernet
· 100 BASE-T Fast Ethernet
· 1000 BASE-T Gigabit Ethernet
· 10G BASE-T Gigabit Ethernet IEEE 802.3
· 155 Mbit ATM
· 1.2 Gbit ATM
PoE++ Type 4 (IEEE 802.3bt) including IEC 60512-9-3/ed.2 (test 9c) and IEC
60512-99-002/ed.1 draft (test 99b)N420.66A Nexans LANmark-6A Snap-In Connector
23.00 AEDAdd to cartN420.66A Nexans
DESCRIPTION
Application
Nexans LANmark-6A Evo Snap-In Connectors are manufactured and tested to the latest Category 6A specifications defined in the International and American cabling standards and are designed to meet or exceed the stringent quality and performance criteria needed to support all applications up to 500 MHz, including 10 Gigabit Ethernet. A fully closed metal rear cover providing 360 degrees shielding offers excellent coupling attenuation and ensures immunity from Alien Crosstalk and other external interferences. Channels built with LANmark-6A cables and jacks do not need on site testing for Alien Crosstalk, as this parameter is met by design. This significantly reduces the installation
cost for 10G network cabling.• 10 BASE-T Ethernet
• 100 BASE-T Fast Ethernet
• 1000 BASE-T Gigabit Ethernet
• 10G BASE-T Gigabit Ethernet IEEE 802.3
• 155 Mbit ATM
• 1.2 Gbit ATM
PoE++ Type 4 (IEEE 802.3bt) including IEC 60512-9-3/ed.2 (test 9c) and IEC 60512-99-002/ed.1 draft (test 99b).N424.532 Nexans UK Style Backbox Single Gang White
7.00 AEDAdd to cartN424.532 Nexans
DESCRIPTION
LANmark Snap-In Modules in standard UK styles
• 25 x 50 mm angled and flat shuttered modules for 1 LANmark Snap-In connector
• LJ6C angled and flat shuttered modules for 1 LANmark Snap-In connector
• 50 x 50 mm angled shuttered modules for 2 LANmark Snap-In connectors Single and Double gang Frames
Various designs of frames to fit the 25 x 50 mm or 50 x 50 mm LANmark Snap-In Modules. Blank Modules To cover unused space in single or double gang frames e.g. when only 1 or 3 ports are required. Single and Double gang Back Boxes Suitable with the single and double gang frames.N424.532 Nexans UK Style Backbox Single Gang White
9.00 AEDAdd to cartNexans N424.532
UK Style Backbox Single Gang White
DESCRIPTION
LANmark Snap-In Modules in standard UK styles
· 25 x 50 mm angled and flat shuttered modules for 1 LANmark Snap-In connector
· LJ6C angled and flat shuttered modules for 1 LANmark Snap-In connector
· 50 x 50 mm angled shuttered modules for 2 LANmark Snap-In connectorsN42i.101 Nexans DIN-Rail Outlets and Boxes
469.00 AEDAdd to cartNEXANS
· For DIN-Rail mount (35mm)
· Data connection for the industry
· For up to 6 copper of fibre optic Snap-In connectors (not included)
· Splice trays as accessories
· For technical enclosures, Wireless Access Points, Industrial cabinets
· Snap-In connectors not included· Robust metal body, powder coated
· IP20 protection rating with individual dust shutters
Possibility of Individual port colour coding through coloured shutter
· up to 6 LANmark RJ45 or GG45 Snap-In jacks
· up to 6 SC Snap-In couplers (6 fibres)
· up to 3 SC duplex Snap-In couplers (6 fibres)
· up to 6 LC duplex Snap-In couplers (12 fibres)
·
· Mix of copper jacks and optic adapters possible
· Strain release through cable gland or tie wraps
· Removable (screws) side cover
Type of cables
· Shielded Industrial Category 6 and 7 data cables, AWG 24 to AWG23
· Fiber optic cables up to 15mm diameter
· Simplex – Duplex and breakout fibre optic cables
· Tight buffer or loose tube fibre optic cables
· Pre-terminated cablesN439.4SNB Nexans LANmark-OF Sliding Patch Panels
290.00 AEDAdd to cartN439.4SNB Nexans
DESCRIPTION
Application
Accepting the range of ST couplers or LANmark-OF snap-ins, these patch panels with sliding mechanism facilitate front side installation.
Compatibility
Suitable for tight buffer cables (direct termination) , Loose tube cables using Splice Cassette / pigtailed terminations. Accepts pre-terminated cable assemblies.