NEXANS
N102.105BK Nexans 1HU Patch Guide with Rings, Black
54.00 AEDAdd to cartNexans
Patch Guides, Blank Panels & Cable Management
Ā· Patch guides to manage and store all patch cords.
Ā· 1 HU and 2 HU for high density.
Ā· 1 HU with rings for easy access.
Ā· Cable guide for all patch panels without clip-on.N116.P1A020OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m Orange
25.00 AEDAdd to cartN116.P1A020OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system ļ¬exibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retroļ¬t Latch Protector, which can be used for colour coding of different services.
N116.P1A030OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m Orange.
25.80 AEDAdd to cartN116.P1A030OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system ļ¬exibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. . LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retroļ¬t Latch Protector, which can be used for colour coding of different services.
N116.P1A050OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m Orange.
43.00 AEDAdd to cartN116.P1A050OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system ļ¬exibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retroļ¬t Latch Protector, which can be used for colour coding of different services.N116.P1A200OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m Orange
100.00 AEDAdd to cartN116.P1A200OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system ļ¬exibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retroļ¬t Latch Protector, which can be used for colour coding of different services.N11A.U1F010OK Nexans LANmark-6A Ultim UniBoot Patch Cords, 1 mtrs
26.00 AEDAdd to cartN11A.U1F010OK Nexans
DESCRIPTION
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an)
and any other future Cat.6A application.
LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched
with other LANmark-6A components to provide improved data throughput in complex
channel conļ¬gurations. Ultim cords use stranded cable and as such provide maximum
system ļ¬exibility for the use at Cross Connects and Consolidation points.
They will also maximise the lifetime and longevity of the system by minimising the risk
of wear & tear damage. Due to their good electrical performance and mechanical
stability, LANmark-6A Ultim cords can be used for accurate ļ¬eld testing of Cat 6A
cabling channels. .
Ultim Cords feature a slim boot for mechanical protection, which is kept inside the
RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit.
They also come with a āReplaceableā Latch Protector, which can be used for colour
coding of different services.N11A.U1F020OK Nexans LANmark-6A Ultim Patch Cord, 2 Meters
31.00 AEDAdd to cartN11A.U1F020OK Nexans
DESCRIPTION
Application
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an) and any other future Cat.6A application. LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched with other LANmark-6A components to provide improved data throughput in complex channel conļ¬gurations. Ultim cords use stranded cable and as such provide maximum system ļ¬exibility for the use at Cross Connects and Consolidation points. They will also maximise the lifetime and longevity of the system by minimising the risk of wear & tear damage. Due to their good electrical performance and mechanical stability, LANmark-6A Ultim cords can be used for accurate ļ¬eld testing of Cat 6A cabling channels. Ultim Cords feature a slim boot for mechanical protection, which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a āReplaceableā Latch Protector, which can be used for colour coding of different services.N11A.U1F030OK Nexans LANmark-6A Ultim Patch Cord 3 mtr
35.00 AEDAdd to cartN11A.U1F030OK Nexans
DESCRIPTION
Application
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an)
and any other future Cat.6A application.
LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched
with other LANmark-6A components to provide improved data throughput in complex
channel conļ¬gurations. Ultim cords use stranded cable and as such provide maximum
system ļ¬exibility for the use at Cross Connects and Consolidation points.
They will also maximise the lifetime and longevity of the system by minimising the risk
of wear & tear damage. Due to their good electrical performance and mechanical
stability, LANmark-6A Ultim cords can be used for accurate ļ¬eld testing of Cat 6A
cabling channels. .
Ultim Cords feature a slim boot for mechanical protection, which is kept inside the
RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit.
They also come with a āReplaceableā Latch Protector, which can be used for colour
coding of different services.N121.4MLY Nexans LANmark-OF Pigtail LC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
20.30 AEDAdd to cartN121.4MLY Nexans
DESCRIPTION
Pigtail characteristics
⢠Fibre assembly to terminate cable with fusion splicing
⢠Suitable for use in patch panels using splice cassettes.
⢠The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkĀOF SM pigtails have LANmarkĀOF SM GIGAliteFLEX ļ¬bre inside.Ā Ā These ļ¬bres are bend insensitive and compliant to ITUĀT G.657.A1 and to IEC 60793Ā2Ā50, ļ¬bre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) withĀ AluminiumĀ protectorsĀ (N890.021).
Maxistrip pigtails are recommended to be used with loose tube cables or MicroĀ Bundle cables, i.e. with 250 um ļ¬bres. When using tight buffer cables (900 um ļ¬bres) additional stress on the maxistrip pigtails should be limited as much as possible
For proper alignment in the fusion splice tool the pigtail is ļ¬xed on the 250 um coating after stripping the 900 um coating.Ā Ā Fixing the pigtail on the 900 um coating willĀ leadĀ toĀ improperĀ alignment.
In addition the pigtail needs to be stripped till the cladding around the splice area beforeĀ insertionĀ inĀ theĀ spliceĀ tool.
N121.4MLY Nexans Pigtail LC/UPC Singlemode 9/125 1m Yellow
20.00 AEDAdd to cartPigtail characteristics
Ā· Fibre assembly to terminate cable with fusion splicing
Ā· Suitable for use in patch panels using splice cassettes.
Ā· The pigtails can be stripped in one action over a long distance up to 100cm.
Fibre type
The LANmarkOF
OM3 pigtails have LANmarkOF
OM3 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.2b. The pigtail jacket is Aqua.
Ā·
The LANmarkOF
OM4 pigtails have LANmarkOF
OM4 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.3b. The pigtail jacket is Aqua.
Ā·
The LANmarkOF
OM5 pigtails have LANmarkOF
OM5 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.4b. The pigtail jacket is Lime Green.
Ā·
The LANmarkOF
SM pigtails have LANmarkOF
SM GIGAliteFLEX fibre
inside. These fibres are bend insensitive and compliant to ITUT
G.657.A1 and to
IEC 60793250,
fibre model B6.a1. The pigtail jacket of the singlemode pigtails is
yellow.N121.5MLA Nexans LANmark-OF Pigtail LC OM3 Maxistrip LSZH 50/125 1m Aqua
19.70 AEDAdd to cartN121.5MLA Nexans
DESCRIPTION
Pigtail characteristics
⢠Fibre assembly to terminate cable with fusion splicing
⢠Suitable for use in patch panels using splice cassettes.
⢠The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkĀOF OM3 pigtails have LANmarkĀOF OM3 GIGAliteFLEX ļ¬bre inside. This bend insensitive multimode ļ¬bre has a small bend radius of 7,5 mm and is compliant to IEC 60793Ā210, ļ¬bre model A1a.2b.Ā Ā The pigtail jacket is Aqua.Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095)Ā withĀ heatĀ shrinkĀ protectorsĀ (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) withĀ AluminiumĀ protectorsĀ (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or Micro Bundle cables, i.e. with 250 um ļ¬bres. When using tight buffer cables (900 um ļ¬bres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is ļ¬xed on the 250 um coating after stripping the 900 um coating.Ā Ā Fixing the pigtail on the 900 um coating willĀ leadĀ toĀ improperĀ alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area beforeĀ insertionĀ inĀ theĀ spliceĀ tool.
N123.4MCY Nexans LANmark-OF Pigtail SC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
21.00 AEDAdd to cartN123.4MCY Nexans
DESCRIPTION
Pigtail characteristics
⢠Fibre assembly to terminate cable with fusion splicing
⢠Suitable for use in patch panels using splice cassettes.
⢠The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkĀOF SM pigtails have LANmarkĀOF SM GIGAliteFLEX ļ¬bre inside.Ā Ā These ļ¬bres are bend insensitive and compliant to ITUĀT G.657.A1 and to IEC 60793Ā2Ā50, ļ¬bre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095)Ā withĀ heatĀ shrinkĀ protectorsĀ (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) withĀ AluminiumĀ protectorsĀ (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or MicroĀBundle cables, i.e. with 250 um ļ¬bres. When using tight buffer cables (900 um ļ¬bres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is ļ¬xed on the 250 um coating after stripping the 900 um coating.Ā Ā Fixing the pigtail on the 900 um coating willĀ leadĀ toĀ improperĀ alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area beforeĀ insertionĀ inĀ theĀ spliceĀ tool.