Fibre Networking
FWE-MOD-12-M-C AFL Modular DIN Rail Mounted Enclosure
1,869.00 AEDAdd to cartAFL FWE-MOD-12-M-C
Modular DIN Rail Mounted Enclosure
DESCRIPTION
AFL specialises in the development of fibre optic enclosures to suit all environments and customer needs. We have developed a complete range to suit almost any application including 19” rack mounting, wall mounting, Defence style, IP-rated for outside
plant environments, industrial uses and for underground terminations.
Our extensive range of enclosures can accommodate a variety of installation applications including fusion splicing, directtermination, pre-terminated cables, MTP connectivity and pre-terminated copper cabling.
In addition, AFL can offer a customer tailored enclosure or cabinet solution to suit non-standard applications.GUSN812 BELDEN 12 Fiber Cable Non Armoured SM
25,000.00 AEDAdd to cartBELDEN GUSN812 (1000 mtr)
Indoor/Outdoor Central Loose Tube 12 Fibers G652D/G657A1-OS2
Product Description
Universal (Indoor/Outdoor) Rodent Protection Central Loose Tube Optical Cable 12 x 9/125-G652D/G657A1-OS2 A/I-DQ(ZN)BH
Technical Specifications
Construction Type:Central Loose TubeGUSND06 BELDEN 6F, MM 50/125 OM3 CLT, UNARMORED OUTDOOR/INDOOR, ORANGE
7,500.00 AEDAdd to cartBELDEN GUSND06 (1000 mtr)
6F, MM 50/125 OM3 CLT, UNARMORED OUTDOOR/INDOOR, ORANG
Product Description
Universal (Indoor/Outdoor) Rodent Protection Central Loose Tube Optical Cable 06 x 50/125-OM3-BI A/I-DQ(ZN)BHNumber of Jackets: Single Jacket
Type of Armor: Non-ArmoredFiber Core Diameter: 50 μm
Max Attenuation at 1300 nm: 1.0 dB/km
Max Attenuation at 850 nm: 2.9 dB/kmGUSND12 BELDEN Indoor/Outdoor Central Loose Tube 12 Fibers OM3
4,200.00 AEDAdd to cartBELDEN GUSND12 (1000 mtr)
Indoor/Outdoor Central Loose Tube 12 Fibers OM3 Product
Product Description
Universal (Indoor/Outdoor) Rodent Protection Central Loose Tube Optical Cable 12 x 50/125-OM3-BI A/I-DQ(ZN)BHTechnical Specifications
Construction Type: Central Loose TubeGUSND24 BELDEN 24F, MM 50/125 OM3 CLT, Unarmored Outdoor/Indoor, LSNH, Standard Rodent Protection
24,500.00 AEDAdd to cartBELDEN GUSND24 (1000 mtr)
24F, MM 50/125 OM3 CLT, Unarmored Outdoor/Indoor, LSNH, Standard Rodent Protection
DESCRIPTION
Universal (Indoor/Outdoor) Rodent Protection Central Loose Tube Optical Cable 24 x 50/125-OM3-BI A/I-DQ(ZN)BH
For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and
indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.N121.4MLY Nexans LANmark-OF Pigtail LC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
20.30 AEDAdd to cartN121.4MLY Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF SM pigtails have LANmarkOF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITUT G.657.A1 and to IEC 60793250, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
Maxistrip pigtails are recommended to be used with loose tube cables or Micro Bundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
N121.4MLY Nexans Pigtail LC/UPC Singlemode 9/125 1m Yellow
20.00 AEDAdd to cartPigtail characteristics
· Fibre assembly to terminate cable with fusion splicing
· Suitable for use in patch panels using splice cassettes.
· The pigtails can be stripped in one action over a long distance up to 100cm.
Fibre type
The LANmarkOF
OM3 pigtails have LANmarkOF
OM3 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.2b. The pigtail jacket is Aqua.
·
The LANmarkOF
OM4 pigtails have LANmarkOF
OM4 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.3b. The pigtail jacket is Aqua.
·
The LANmarkOF
OM5 pigtails have LANmarkOF
OM5 GIGAliteFLEX fibre inside.
This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is
compliant to IEC 60793210,
fibre model A1a.4b. The pigtail jacket is Lime Green.
·
The LANmarkOF
SM pigtails have LANmarkOF
SM GIGAliteFLEX fibre
inside. These fibres are bend insensitive and compliant to ITUT
G.657.A1 and to
IEC 60793250,
fibre model B6.a1. The pigtail jacket of the singlemode pigtails is
yellow.N121.5MLA Nexans LANmark-OF Pigtail LC OM3 Maxistrip LSZH 50/125 1m Aqua
19.70 AEDAdd to cartN121.5MLA Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF OM3 pigtails have LANmarkOF OM3 GIGAliteFLEX fibre inside. This bend insensitive multimode fibre has a small bend radius of 7,5 mm and is compliant to IEC 60793210, fibre model A1a.2b. The pigtail jacket is Aqua.Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or Micro Bundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
N123.4MCY Nexans LANmark-OF Pigtail SC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
21.00 AEDAdd to cartN123.4MCY Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF SM pigtails have LANmarkOF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITUT G.657.A1 and to IEC 60793250, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or MicroBundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
N205.617 Nexans Duplex LC Snap-In Adaptor Multimode Aqua
23.00 AEDAdd to cart11.4mm
Technical Specifications
Insertion Loss: < 0.2 dB
Sleeve Preservation Strength: 2.0 ~ 5.9N (200gf ~600gf)
JIS Z9015 standard l: 1 time pull out
NAMl test AQL = 0.25%
Plug Connect/Disconnect Strength: Less than 19.6N (2Kgf)
Sealing Pull Strength: Less than 98.0N (10Kgf)